wvc-tool

WVC-Inverters Tool

wvc-tool.py Dev orientation Manual

build-in AutoGet "modemID" (FA) Default: Yes if "-m" is not selected.

		//	Payload	:	'\FA\xFF\xFF\xFF\xFF\xFF\xFF\x6D'
			Output	:	range '00000000-FFFFFFFF' : 'ser.read(8)	a.k.a "modemID"//

build-in Test Modem connection

		// Payload = b'\xF8\xFB\x04\x11\xE3\xFF\xFF\x6B' # test modem connection
			Output : 'f8fb0411e3ffff6b' ser.read(8)
		
		if bytes(s).hex() == 'f8fb0411e3ffff6b': ---- "F8<modemID(8)><inverterID(4)>6B"
print("Modem connection testing ... :" , bytes(s).hex() , "-" , "OK!")

else: print("Modem connection testing ... :" , bytes(s).hex() , "-" , "Fail!") //

		if "-q" missing Print: Payload and Output

-o wvc.ini Optional. Inverter's configuration file path. Multi Units. Default: "On", even if not selected in case "wvc.ini" named file located/detected in same folder. This option sub argument will define custom named configuration file's path. value of wvc.ini will be taken if "-o" is selected, but it's sub argument's missing.

-i ID Inverter's ID. Single unit. (XXXX) This Option is mandatory, if "-o" option's missing in front. It can be skipped if "-o" is selected, and a file defined or wvc.ini named file, contains proper Inverter ID entrys is located in the same folder. If not selected and "-o" is missing or it's custom defined configuration file's content is incorrect/corupted/syntax_errors etc. It's sub argument is missing and/or the default "wvc.ini" file is missing or is empty or incomplete Print: "-i is a MANDATORY Option if "-o" isn't defined", folowed by the General Help.

		If selected, "ID" must be defined, otherwise,
		Print: "You must define ID".

		"Type"  - Inverter model from current "lookup" file:
		WVC295, WVC300, WVC350, WVC600, WVC850, WVC1200.
		Type can be determinated by ID :
		
		WVC295: 2000-3FFF
		WVC300: 4000-5FFF
		WVC350: 6000-7FFF
		WVC600: 8000-9FFF
		WVC800: A000-BFFF
		WVC1200: C000-FFFF
		
		!!!!! Inverter also has a variant : "A": 120V and "B" 230V
		to be determinated by F2 (realtime status) ???????????? 

		"ID" 	- Inverter ID.
		Located on the Inverter.
		value range: 0000-FFFF

-d /dev/ttyX:9600 Optional. Phisical Serial device path and port speed. USB, RS232 etc. If selected, sub argument must be defined, otherwise, Print: "Device path must be defined'. Default is "On", even not selected, with "/dev/ttyUSB0:9600" as a default value.

	//	serialPort = serial.Serial("/dev/ttyUSB0", 9600)	//

-n IP:Port Optional. Ser2net connection IP and Port. Requires "-o" or "-i". If "-n" is selected and "-o" or "-i" are not, Print: "-n requires "-o" or "-i" to be selected in front". If selected, "-d" sets "Off" and "physical" serial connection is replaced by "ser2net" connector. This option requires sub argument, otherwise, Print: "IP:Port" must be defined.

	//	serialPort = serial.serial_for_url('rfc2217://192.168.78.13:7000', timeout=1)	//

-m XXXXXXXX Optional. Manual modemID (8) Default: Off - (Auto "FA") If selected, "FA" is skipped and it's variable "modemID", taken from here. Requires "-i", if not, Print: "-m requires -i to be selected in front" Sub argument must be defined, otherwise, Print: "modemID must be defined". values range: 00000000-FFFFFFFF

-s XX Real time data Sample (F2) Requires "-o" or "-i". If "-s" is selected and "-o" or "-i" are not, Print: "-s requires "-o" or "-i" to be selected in front". Optional sub argument: value range: 1-99 It is the number of cicles to be rolled and infinity loop if sub argument is missing.

		//	Payload : 'F2<modemID><InverterID>65'
			Output	: ser.read(17)	//

		DevOpsOnly: mtb setup Working "Realtime Stats"

		//	Payload:	'\xf2\xfb\x04\x11\xe3\x88\xce\x65'	//

-p xxxx Inverter Power Switch. (F3/F4) Requires "-o" or "-i". If "-p" is selected and "-o" or "-i" are not, Print: "-p" requires "-o" or "-i" to be selected in front". sub argument must be defined if "-p" is selected, otherwise, Print: "action for "-p" must be selected. on, off or restart

		// Payloads:		

		on	=	'F3<modemID><InverterID>66'
		on_Output:		'F3<modemID><InverterID>66' : ser.read(8) = OK. Done. Command Accepted.

		off	=	'F4<modemID><InverterID>67'
		off_Output:		'F4<modemID><InverterID>67' : ser.read(8) = OK. Done. Command Accepted.

		restart	=	'off+sleep5+on'	//

		if "-q" missing Print: Payload and All Output

-b MQttIP:Port Data collection and MQtt publisher. (F5) Requires "-o" or "-i". If "-b" is selected and "-o" or "-i" are not, Print: "-b requires "-o" or "-i" to be selected in front". publish to MQtt using "paho-mqtt" If sub argument is missing and "-q" missing, Print: Inverter Real coverted Output data in Infinity loop on screen (much as "-s").

		//	Payload:	'F5<modemID><InverterID>68'
			Output:		ser.read(28)	//

-r Optional. Resets Inverter's Power-Meter Counter

		//	Payload:	'F0<modemID><InverterID>00'
			Output:		'F0<modemID><InverterID>00' : ser.read(8) = OK. Command Accepted.
		if "-q" missing Print: Payload and Output

-a XX Adjust Output's (AC) Power. values range: 01-64 (64=100%)

		//	Payload:	'F1<modemID><InverterID><01-64>'
			Output:		'F1<modemID><InverterID><The same return value>' : ser.read(8) = OK. Command Accepted.
		if "-q" missing Print: Payload and Output

-w XX Optional. Adds a delay in Cicle's begining. Default: "Off" Requires -b or -s if selected, and ofcource "-o" or "-i" selected in front. value range 1-99 (sec)

-l wvc.log Optional. Custom Log filename path. If sub argument's missing will create wvc.log. Default: "Off"

-q Quiet. Cuts All on-screen output.

-p wvc.pid Custom Pid fliename path. If not selected or empty sub argument, will create wvc.pid in case "-f" is selected.

-f Fork in background.

-h Help. This Screen.